Oil/Gas/Biomass Fired Boiler

Industrial Applications

Pharmaceutical
Tabacco
Texttile
Rubber Plastic
Paper Making
Hotel
Food Processing
Chemical

Brief Intro:

The hot air boiler is a new type of high-efficiency and energy-saving heat exchange equipment with air as the heat transfer medium. MIE Hot Air Boiler has advanced design technology, covering the temperature range of medium and low temperature, medium temperature and high temperature, and the type can be customized according to fuel or site requirements.

Introduction:

The hot blast stove is a new type of high-efficiency and energy-saving heat exchange equipment with air as the heat transfer medium. It can continuously provide clean hot air with constant temperature, constant pressure and dust-free. The combustion chamber of the hot blast stove is integrated with the heat exchanger, and adopts an all-steel plate multi-layer sleeve structure. The lower part of the furnace core is a combustion chamber, and the upper part and surrounding are annular heat exchangers. The heat exchange of the air and the flue gas makes the air and flue gas continuously exchange the direction of rotation while traveling, which greatly enhances the heat exchange efficiency.

 

There are many varieties and series of hot air boilers, which can be customized according to actual fuel or site requirements. In many industries, they have become the replacement products of electric heat sources and traditional steam power heat sources.

(1) The hot air boiler series has mature technology, a high degree of automation, strong reliability, and accurate temperature control. It adopts enhanced heat transfer method and heat-resistant steel material, with a compact structure, small volume, and long service life.

 

(2) The clean hot air is output, and the heat exchange device is used to heat the air indirectly, so that the flue gas and the air go their own way, and the heating is pollution-free. It meets the needs of applications with clean, fire, and explosion-proof requirements for hot air.

 

(3) The hot blast stove directly transports and supplies the flue gas after the full combustion of different fuels to the heating equipment, which has a very high thermal efficiency.

 

(4) The user can choose a more suitable boiler form according to the operating temperature, fuel, or layout conditions.

Parameter

Model

Rated Calorific Value

Output Air Volume

Output Temperature

Gas Consumption

Unit

Kcal

M³/h

M³/h

 

0.1

10x 10^4

1500-560

60-200

8-15

 

0.2

20x 10^4

3500-930

60-200

10-25

 

0.5

30x 10^4

5600-1480

60-200

15-40

 

0.7

40x 10^4

12000-2160

60-250

15-55


1

60x 10^4

25000-4330

60-250

20-75

 

2

120x 10^4

28000-5600

60-250

30-150

 

3.2

200x 10^4

45000-8660

60-250

50-245

 

4

240x 10^4

83000-12500

60-350

65-275

 

5

300x 10^4

134400-23000

60-350

80-355

 

6

360x 10^4

170000-28000

60-350

110-425

 

8.3

500x 10^4

250000-433000

60-350

150-600

10

600x 10^4

320000-572000

60-351

150-600

NOTE: –

1. Parameter is for reference only.

2.  Our company can provide various types of specialized boilers to meet specific user needs.

Get An Instant Quotation